Treatment method of insulation fault of power transformer

Treatment method of insulation fault of power transformer

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2020-12-21 11:19
  • Views:

(Summary description)At present, the most widely used power transformers are oil-immersed transformers and dry-type resin transformers. The insulation of power transformers is the insulation system composed of transformer insulation materials. It is the basic condition for the normal operation and operation of the transformer. The service life of the transformer is determined by It is determined by the life of the insulating material (that is, oil paper or resin, etc.).

Treatment method of insulation fault of power transformer

(Summary description)At present, the most widely used power transformers are oil-immersed transformers and dry-type resin transformers. The insulation of power transformers is the insulation system composed of transformer insulation materials. It is the basic condition for the normal operation and operation of the transformer. The service life of the transformer is determined by It is determined by the life of the insulating material (that is, oil paper or resin, etc.).

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2020-12-21 11:19
  • Views:
Information

At present, the most widely used power transformers are oil-immersed transformers and dry-type resin transformers. The insulation of power transformers is the insulation system composed of transformer insulation materials. It is the basic condition for the normal operation and operation of the transformer. The service life of the transformer is determined by It is determined by the life of the insulating material (that is, oil paper or resin, etc.).

Practice has proved that most of the damages and failures of the transformer are caused by the damage of the insulation system. According to statistics, accidents caused by various types of insulation faults account for more than 85% of all transformer accidents. For transformers that operate normally and pay attention to maintenance and management, their insulating materials have a long service life. Therefore, protecting the normal operation of the transformer and strengthening the reasonable maintenance of the insulation system can to a large extent ensure that the transformer has a relatively long service life, and preventive and predictive maintenance is the key to improving the service life of the transformer and improving the reliability of power supply .

In oil-immersed transformers, the main insulating materials are insulating oil and solid insulating materials, insulating paper, cardboard, and wooden blocks. The so-called aging of transformer insulation means that these materials decompose due to environmental factors, reducing or losing their insulation strength.

part 1

Solid paper insulation failure

Solid paper insulation is one of the main parts of oil-immersed transformer insulation, including: insulation paper, insulation board, insulation pad, insulation roll, insulation binding tape, etc. Its main component is cellulose, and the chemical expression is (C6H10O6)n, formula Where n is the degree of polymerization. Generally, the degree of polymerization of new paper is about 1300. When it drops to about 250, its mechanical strength has dropped by more than half. The degree of polymerization at the end of life due to extreme aging is 150-200. After the insulation paper ages, its degree of polymerization and tensile strength will gradually decrease, and water, CO, CO2 will be generated, followed by furfural (furaldehyde). Most of these aging products are harmful to electrical equipment, and will reduce the breakdown voltage and volume resistivity of the insulating paper, increase the dielectric loss, decrease the tensile strength, and even corrode the metal materials in the equipment. Solid insulation has irreversible aging characteristics, and the aging reduction of its mechanical and electrical strength cannot be restored. The life of the transformer mainly depends on the life of the insulating material. Therefore, the solid insulating material of the oil-immersed transformer should have good electrical insulation and mechanical properties, and after years of operation, its performance will decline slowly, that is, good aging characteristics.

1. The performance of paper fiber materials.

Insulating paper fiber material is the most important insulating component material in oil-immersed transformers. Paper fiber is the basic solid tissue component of plants. Among the atoms that make up the material molecule, there are positively charged atomic nuclei and negatively charged electrons orbiting the atomic nucleus. The difference between conductors is that there are almost no free electrons in the insulating material, and the very small electric current in the insulator mainly comes from ionic conduction. Cellulose is composed of carbon, hydrogen, and oxygen. In this way, because of the presence of hydroxide radicals in the molecular structure of cellulose, there is a potential for the formation of water, which makes paper fibers have water-containing properties. In addition, these hydroxide radicals can be considered as the center surrounded by various polar molecules (such as acid and water). They are combined by hydrogen bonds, making the fiber vulnerable to damage: at the same time, the fiber often contains a certain proportion (about 7%). About) impurities, these impurities include a certain amount of water, because the fiber has a colloidal nature, so that these water can not be completely removed. This also affects the performance of paper fibers.

Polar fibers are not only easy to absorb moisture (moisture makes a strong polar medium), and when paper fibers absorb water, the interaction force between hydroxide radicals becomes weaker, and the mechanical strength deteriorates sharply when the fiber structure is unstable. Therefore, paper insulating parts generally need to be dried or vacuum-dried and immersed in oil or insulating varnish before they can be used. The purpose of varnishing is to keep the fiber wet. To ensure that it has higher insulation and chemical stability and has relatively high insulation and chemical stability. High mechanical strength. At the same time, after the paper is sealed with lacquer, it can reduce the absorption of water by the paper, prevent the material from oxidizing, and also fill the gaps to reduce the bubbles that may affect the insulation performance, cause partial discharge and electrical breakdown. However, some people think that after dipping the paint and then immersing in the oil, some paints may slowly dissolve into the oil and affect the performance of the oil. Pay attention to the application of this type of paint.

Of course, the properties of fiber materials with different components and the different qualities of fiber materials with the same composition have different impacts and performances. For example, cotton has the highest fiber content and hemp fiber is the strongest. Some imported insulating paperboards are processed well due to their good processing and processing. The performance is obviously better than some domestic cardboard materials. Most of the insulating materials of transformers are insulated with various types of paper (such as paper tape, cardboard, paper pressure forming parts, etc.). Therefore, it is very important to choose insulating paper materials with good fiber raw materials in the manufacture and maintenance of transformers. The special advantages of fiber paper are strong practicability, low price, convenient use and processing, simple and flexible forming and handling when the temperature is not high, light weight, moderate strength, and easy to absorb impregnating materials (such as insulating paint, transformer oil, etc.).

2. The mechanical strength of paper insulation materials.

In addition to the fiber composition, density, permeability and uniformity of the paper, the most important factors for selecting paper insulation materials for oil-immersed transformers also include the requirements for mechanical strength, including tensile strength, punching strength, tear strength and toughness:

① Tensile strength: When the paper fiber is subjected to tensile load, it has the maximum stress that it can withstand without being broken

② Punching strength: a measure of the ability of paper fibers to withstand pressure without being broken.

③ Tear strength: the force required to tear the paper fiber is required to meet the corresponding standards.

④ Toughness: the strength of paper folded or cardboard can meet the corresponding requirements.

To determine the performance of solid insulation, you can try to take samples to measure the degree of polymerization of paper or cardboard, or use high-performance liquid chromatography to measure the furfural content in the oil, so as to analyze whether there is a fault in the transformer, whether it involves solid insulation or whether there is a local aging of the coil insulation Low temperature and overheating, or judge the aging degree of solid insulation. In the operation and maintenance of paper fiber insulation materials, attention should be paid to controlling the rated load of the transformer, and the operating environment is required to have good air circulation and heat dissipation conditions to prevent the transformer from exceeding the standard temperature rise and the tank body from lack of oil. It is also necessary to prevent the accelerated aging of the fiber caused by oil pollution and deterioration, which will damage the insulation performance, service life and safe operation of the transformer.

Scan the QR code to read on your phone

Related news

Characteristics

Characteristics of insulating materials

The insulating material has good chemical resistance. Insulating materials are mostly shiny translucent objects, and some are partially transparent.
2020-12-21
Are

Are high-temperature-resistant coatings and fire-resistant materials the same thing?

Many people confuse high-temperature-resistant coatings with fire-resistant coatings, thinking that they can withstand high temperatures, so fire protection should also be possible, but in fact there is an essential difference between the two. The high temperature outside and the baking on the flame are not the same. The "function" of the two is common.
2020-12-21
A

A brief introduction to the combustion resistance of insulating sheets

Insulating sheet is a material that can prevent the passage of electric current. Its resistivity is very high, usually in the range of 10 to 10Ω·m.
2020-12-21
What

What are the characteristics of wear-resistant coatings?

Few people know about wear-resistant coatings. It is a new type of functional coatings with good durability and durability. It is usually used on metal surfaces or lenses and glass, so that it has more wear resistance, so that it will not be scratched. So, today the editor will give you a specific introduction to the characteristics of wear-resistant coatings? What are the precautions for the use of wear-resistant coatings.
2020-12-21

Feedback

Username used for comment:
客户留言
Description:
验证码
FENGBAO

Contact

Address: No. 18, Wangtian Road, Luoxi Town, Xinbei District, Changzhou City, Jiangsu Province
Tel:
+86 
18651989127
Fax: +86 0519-86323663

code

Mobile browsing

Changzhou Feng Bao Insulation Material Co., Ltd.      苏ICP备2020059708号-1       Powered by: www.300.cn Changzhou